Set it up per system
Add your segments and your leak grades to the template, so every surveyor records them the same way.
Most leak surveys happen where the phone has no bars. This form saves on the phone anyway, records which segment you walked and with what instrument, and keeps every leak you find tied to its repair.
Pipeline Leak Survey
Pipeline Leak Survey
Field status
Saved offline · syncs on reconnect
Interactive checklist
0 of 9 checked
Field workflow
Add your segments and your leak grades to the template, so every surveyor records them the same way.
Record the instrument before you start. The form saves on the phone without signal and syncs when you are back in coverage.
Mark each leak as a failed item with its reading, grade and photo. A hazardous leak still gets handled under your emergency procedures first.
Every failed item becomes a corrective action with an owner and a due date. The repair, the recheck and the closeout stay with the survey.
Built for the job
A leak survey record has to answer the same questions years later: which pipe, when, how it was checked, and what happened to each leak.
Line or system ID, the start and end of the segment walked, class location or business district, surveyor name, and the date of the survey.
Leak detector type and serial number, last calibration or bump test, and the method used, such as walking, mobile or a check at manholes and pavement cracks.
Weather and ground conditions that affect readings, and any part of the segment you could not survey, with the reason.
Location or GPS point, reading, the leak grade your procedures use, a photo, and whether you made the area safe before leaving.
Who owns the repair, the due date your procedures set for that grade, the date it was repaired, and any recheck after the repair.
A survey that found no leaks still gets a record with a date and a name. Without it, nothing shows the survey happened on time.
Compliance & proof
Federal rules for gas pipelines set minimum leak survey intervals in 49 CFR Part 192. Transmission lines are surveyed at intervals not exceeding 15 months, at least once each calendar year, with shorter intervals in Class 3 and 4 locations for lines carrying unodorized gas (192.706). Distribution systems are surveyed with leak detector equipment at least once each calendar year in business districts and at least once every 5 calendar years outside them (192.723). Hazardous leaks must be repaired promptly (192.703). State programs and your own procedures can require more.
It does not replace your operations and maintenance procedures or the rule text. Survey intervals, leak grading and repair deadlines depend on your system, your state and your procedures.
Questions from the field
BasinCheck saves each leak survey with the surveyor, time and location, works without signal, and turns every leak into a corrective action with an owner and a due date.
In BasinCheck
Inspection and JSA connected
Failed item assigned and tracked
Evidence retained for review